Separate names with a comma.
Lopezjm2001. Using a gen 2, in OOG mode ICE don't spin. This is what we read on the can bus. As you said max speed is 85 km/h then MG1 rpm...
Yes it is dc. This data come from can bus and is given by the nimh ecu. I was driving using less then 50A as often as possible in order to reduce...
You can get it, for example, in this post And this one also :)
..............
Lpz I don't know why you send 7E0 2 21 E1 before 7E0 2 21 42, but this first pid is used to get the number of dtc (according to berkeley...
M. Chenyj So your system have 24% losses (3,8 kWh and 5 kWh) Add losses due to charging nimh during trip, because "low" power dc/dc...
Which dongle or device connected on the canbus do you use ?
You probably think CanView ?
jdh2550 From Nimh, you may have 10% lost (from the 24 kW) in the boost converter, MG2_IGBT and in MG2 = 2.4 kW From MG1 to MG2 you have MG1 lost,...
I have a gen2. Yes, Lopezjm you are right, just add ICE power and Battery Power give total combined power. It would have been better reducing...
Yes. For example this one: Power in kW [ATTACH] Horizontal axis is time (10 points/second) The combined power (light blue curve) have been up to...
all. Yesterday I done a nice test drive. Using OOG mode, the speed was between 50 and 55 km/h ( 31 to 34 mph), average 44 km/h. The EV...
Yes, byte 1 = 21 so temp is your rxdata(2) I have already read more then 55°C (see picture using 22 kW) and more then 60°C in an other test,...
Converter temp: In the frame 21, byte 3. (This is the most important in OOG mode.) Inverter MG1 in the frame 23 byte 8. :)
Lopezjim. You send 7E2 30 between each frame received (frames 10 21 22 23 24). It seems that canview do this. I don't do this, just send...
MG2 Temp is received on the "24" frame In this frame you have : byte 1 = 24 byte 2 = MG2 inverter temp byte 3 = MG2 temp byte 4 = MG1 temp. What I...
Kenny_p. You have two parts: High voltage You "just" have to connect on the oem_nimh_pack a lithium_pack. Between these 2 packs insert a...
E2 is the #2 ecu. You may talk to #0 and #3. Why 02 ? That is a good question;) . I send it since several years ago. It work fine but may be it is...
Lopezjm2001. For exemple, in order to receive the MG temp, you would send 07 E2 02 21 C3 Then you will receive one response with 8 bytes,...
Thank you fwd. But, for example, if using 4 kWh during a trip (what I did with my 4,5 plug-in), that would say 3 kWh from A123 and 1 kWh from...