I saw this too during braking. When driving with bms+ and only the stock nimh. I think bms+ don't let voltage going over 245v, unlike the hsd that...
Austrian. Glad to see how these 5 boxes are worldwide known :D Perkins bms is very well documented for example in Battery Vehicle...
As far as I know, nobody has serialy connected 2 oem nimh cells. They where always paralleled. That's to say the + pole with the other + pole....
Damned. The contactor is dead. Welding would say that you had a high amperage during opening or closing the N°3 main relay. So an important...
If you done "cross" connection, may be the contactor is ok. Check if you have some voltage between the two side of this contactor. Zero would be...
neg contactor stuck closed. P0aa4 is number 3 system main relay (wich is close the hall sensor) I suppose you have this dtc when power is off ?...
No, my charger don't go in cv mode. It have a max voltage of 256v and my 70 cells goes up to 246v (3.52v*70. 3.52v is an average). I asked for a...
In hybrid mode just with nimh cells I already saw voltage up to 270v during regen and engine did not came in compression mode. I don't think...
All. Outside temp goes over 10°C. So I done a drive testing in the "OOG" mode, say mode without heater... :D You can drive in 100% EV up to...
Sorry, I am not sure having well understood your question. The last link I give come from here: Installation Instructions | Prius Gen 2 and this...
Have you seen the tests: Plug-In Prius Conversion MPG and Emission Test Results | Plug-In Supply May be they connect their own ecm that control...
Just one idea. Not to be done if you are not "the king of the can bus"::third: You could imagine cutting the 12v power to the toyota ecm, then...
Before driving without gas at high speed, I have on other question: I don't see in the pdf a bridge on the can bus. Bms+ is a bridge so nimh ecu...
You have rear control board here : http://diy.pluginsupply.com/files/rear-controller-description.pdf :)
cpraudio. One of the HV wire is probably connected directly on the nimh cells, not on a nimh contactor In this pdf:...
3,2v is a little lower then our A123 (3,3v). But 72x3,2v is ok = 230v End voltage will be 210/72=2,9v. It is also ok. 3,8v is high. Are they...
All cells are serialy connected. If you use less then, say, 69 cells, voltage will be too low and it will be impossible to connect these cells...
In order to control bms+ you only need sending a pid 556 with the good data (end voltage or orig or soc) And to receive bms+ messages just read...
I think you where talking about the resistor connected outside the charger, for amperage controling. But now I think it was about voltage modif...
No, I have not received it. I would have but it has not been send :mad: