Separate names with a comma.
If the HV Battery is getting hot, it is possible to turn on the battery fan with an Xgauge. I have done this and this does improve HV battery...
Hello Everyone, Today we took delivery of the Prius v Five. Sea Glass Pearl with a Bisque interior. Someone posted that with out pictures, it...
Yes, I Cheat much more in my Prius than I have in any other car. There is no regen below 7mph and I tend to let off the brake peddle a little at...
I also got in. However, there is little activity. I think that almost all Enginer users have removed there systems from the cars. I have 3 systems...
Hello Everyone, I have put a deposit on a 2014 Prius v Five. I expect to take delivery this coming week. Has anyone else taken delivery of a...
Hello Everyone, I have worked with 3prongpaul for about 3 years. He is one of the most knowledgeable people I know in the PHEV modification...
Hello Everyone, Last spring I pulled all the extra batteries out. The Enginer system is setting on the floor next to the car. I have now been...
Hello VTAERO, Realize that your AC and just about everything in the Prius runs with the ICE off. There is no reason to set in the car and let the...
Hi szgabor, The Gen2/3 HV battery is 1.3kwhr. So between 45% and 75% you are adding about 0.4kwhr. The charger will start at about 200v and end at...
Hi Bill, I said "Mostly EV". I accelerate normally to 41mph and then let off to kill the ICE and then run with the ICE at 0rpm on the scangauge. I...
About the original question. I do this all the time. I have an old Enginer PHEV system on the floor in my garage. The Enginer system has lost...
Hello Pedaler, No, your Prius is fine. Do not take it to the dealer. Get a ScanGauge and clear the code. The problem is a known problem with the...
Hi Alpha, mmmodern is not being too harsh. In fact what he states is very real. I have 2 converted Prius that I did more for enjoyment than for...
Hi Alpha, Not enough information here. The best general advise I would give is to go find an installer that has an ongoing installation shop and...
Hi wb9k, Thanks for the added comments. I am not knowledgable on the active system hardware so my thinking on that was only theoretical. So the...
Hi wb9k, Thanks for this coment and a NUGET. You state capacitors. In acutallity all the top balance BMS systems I have seen are not capacitors...
Hi Tex, No, Powin is not an installer. I have been to their site. They are the import warhouse that got stuck with the extra Enginer inventory...
Yes, I can see that the "hit it hard, then back off" can be a good approach. We almost need to do this "hit it hard" to turn on the drain...
Hi W, Thanks again for this information. These are Pouch cells. They are built at 8.2mm thickness. They are stacked 16 pouches high and then put...
Let me go on to another battery question. I had someone associated with Realforce tell me that this was most likely not plating but rather a...